H-7028 Fully Automatic 28 Parameter Hematology Analyzer (5 Diff.)
H-7028
(Less Service, More Stable)

PDF Brochure - Page 1

PDF Brochure - Page 2

PDF Brochure - Page 3

PDF Brochure - Page 4

PDF Brochure - Page 5

H-7028 Fully Automatic 28 Parameter Hematology Analyzer (5 Diff.) (Less Service, More Stable) is a multi-parameter automated Hematology Analyzer designed for clinical laboratories, offering WBC, RBC, PLT, 5-diff, and 24 other testing parameters. The analyzer uses light scatter and impedance technology for WBC differential and impedance method for RBC and PLT. With the most updated technology and concepts, it best meets most clinical laboratory requirements for an automated hematology analyzer. The equipment offers user-friendly software, powerful functions and accurate results.

The H-7021 offers 3 differential tests, while the H-7028 offers 5 differential tests.
The H-7028 offers several additional tests, including:

NEUT (#): Neutrophil Count
NEUT (%): Neutrophil Ratio,
LYMPH (#): Lymphocyte Count,
LYMPH (%): Lymphocyte Ratio

MXD (#): Eosinophil, Basophil and Monocyte Count
MXD (%): Eosinophil, Basophil and Monocyte Ratio

RDW-SD: Red Blood Cell Distribution Width - Standard Deviation
RDW-CV: Red Blood Cell Distribution Width - Corpuscular Volume

Measuring Principles

  • Fluorescence Flow Cytometry Technology/cytochemical flow cytometry using Semi-Conductor LASER and Dye Reagents for WBC and 5 Differential for WBC.
  • Hydrodynamic Focus/impedence/optical focus flow detection method for RBC & PLT Analysis.
  • Cyanide free SLS/Photometric – Hemoglobin method for HGB measurement.
  • Automatic Sampling with Bar Code

 

Technical Specifications

Parameters

28 parameters +3 histograms + 1 scattergram

NEUT (#): Neutrophil Count
NEUT (%): Neutrophil Ratio

LYMPH (#): Lymphocyte Count
LYMPH (%): Lymphocyte Ratio

MXD (#): Eosinophil, Basophil and Monocyte Count
MXD (%): Eosinophil, Basophil and Monocyte Ratio
RDW-SD: Red Blood Cell Distribution Width - Standard Deviation
RDW-CV: Red Blood Cell Distribution Width - Corpuscular Volume

WBC (#): White Blood Cell Count
RBC (#): Red Blood Cell Count
MONO (#): Monocyte Count
MONO (%): Monocyte Ratio
GR (#): Granulocyte count
GR (%): Granulocyte Ratio
HGB (#): Hemoglobin Count
HGB DW: Hemoglobin Distribution Width
MCH: Mean Corpuscular Hemoglobin
MCHC: Mean Corpuscular Hemoglobin Concentration
MCV: Mean Corpuscular Volume
HCT (#): Hematocrit Count
PLT (#): Platelet Count
PCT: Prolactin Count
MPV: Mean Platelet Volume
PDW. Platelet Distribution Width
RTC: Reticulocyte Count
WBC Histograms: White Blood Cell Histograms
RBC Histograms: Red Blood Cell Histograms
PLT Histograms: Platelet Histograms

Baso Histograms: Basophil Histograms
WBC  (White Blood Cell) Differential Scattergram
NEUT (#): Neutrophil Count
NEUT (%): Neutrophil Ratio
BASO (#): Basophil Count
BASO (%): Basophil Ratio
EOS (#): Eosophil Count
EOS (%): Eosophil Ratio
P-LCR (#): Platelet Large Cell Ratio
ALY (#): Atypical Lymphocyte Count
ALY (%): Atypical Lymphocyte Ratio
LIC (#): Limiting Isorrheic Concentration Count
LIC (%): Limiting Isorrheic Concentration Ratio

These extra parameters are available on the H-7028 and not on the H-7021:
(NEU#, NEU%, BAS#, BAS%, EOS#, EOS%, RDW-SD #, RDW-CV #, P-LCR #, ALY #, ALY%, LIC#, LIC%, BASO #, RSC # Histogram)

Measuring Principle

Fluorescence Flow Cytometry Technology/cytochemical flow cytometry using Semi-Conductor LASER and Dye Reagents for WBC and 5 Differential for WBC.
Hydrodynamic Focus/impedance/optical focus flow detection method for RBC & PLT Analysis. Cyanide free SLS/Photometric – Hemoglobin method for HGB measurement.
Measuring Principles LIC

Sample Volume Min 20uL EDTA Whole Blood
Throughput (T/hr) 60 samples per hour or above
Operating System Windows 7 or later
PC Hardware Must be purchased separately (Labomed, Inc. does not sell it)
RAM ≥ 1GB, HDD: 160 GB SATA
Display

≥ 17” LCD Color Monitor

Data Storage Min  10,000 test about  patients
Discrete Mode CBC Mode CBC+DIFF Mode
Power Supply 230V AC, 400W, 50Hz, locally compatible mains plug, set of replacement fuses (if replaceable type used) 
Dimensions 400 x 420 x 490mm
Weight 25kg

Accessories

• Roller Mixer for Homogenous mixing of Blood - one (Optional)

• One set Startup Reagents (Optional)

• Reagents for 5000 test at user end (Optional)

 



Top of the Page

Labomed Inc. is certified by ISO 9001, CE Conformity and is FDA Licensed.

click here to fill out the Information Request Form

Labomed Inc.
Labomed, Inc. Mailing Address: 2728 S La Cienega Blvd.
Los Angeles, CA 90034 U.S.A TEL (310) 202-0814  FAX (310) 202-7286

Send mail to Company Webmaster with questions or comments about this web site.